NuTone 744FLNT Bedienerhandbuch

Stöbern Sie online oder laden Sie Bedienerhandbuch nach Haushaltsfans NuTone 744FLNT herunter. NuTone 744FLNT Instructions / Assembly Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Page 1
MODEL 744FLNT
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Never place a switch where it can be reached from a tub or
shower.
8. Do not use a dimmer switch to operate the light in this unit.
9. Install this unit in a flat ceiling only.
10. For use in non fire rated installations only.
11. Not for use in environmental air handling spaces.
12. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
13. Do not install in a ceiling thermally insulated to a value greater
than R40.
14. This unit must be grounded.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, use the cardboard protector (provided) to keep
drywall spray, construction dust, etc. off power unit.
3. The fluorescent bulb used with this product twists into the bulb
socket. Do not attempt to insert or remove bulb by pushing
it straight in or pulling it straight down.
4. Please read specification label on product for further
information and requirements.
RECESSED
FLUORESCENT FAN / LIGHT
READ AND SAVE THESE INSTRUCTIONS
To clean trim ring / baffle: Vacuum with a soft brush attachment
or remove trim ring / baffle and clean with a soft cloth and mild
soap or detergent. Dry thoroughly before reinstalling.
To clean inside of housing: Remove trim ring / baffle and
vacuum inside of housing with a soft brush attachment.
OPERATION
The fan and light can be operated using various combinations of
on/off switches and controls:
• Fanandlightcontrolledwithsingleon/offswitch
• Fanandlightcontrolledwithseparateon/offswitches
• Fancontrolledwithtimercontrol
• Fancontrolledwithspeedcontrol
See “Connect Wiring” section for various wiring options.
CLEANING
MAINTENANCE
WARRANTY
Motor is permanently lubricated. Do not oil or disassemble motor.
See “Service Parts” section for a list and illustrations of service parts.
NuTone Ventilation Fan/Lights - Limited Warranty
WARRANTY PERIOD: NuTone warrants to the original consumer purchaser of its NuTone Ventilation
Fan/light (the “Fan”) that your Fan (excluding lamps/bulbs) will be materially free from defects in
materials or workmanship for a period of three (3) years from the date of original purchase. The
warranty on the lamps/bulbs provided with the Fan is one (1) year and does not cover lamp/bulb
breakage. This warranty does not cover accessories, such as speed controls, that may be purchased
separately and installed with the Fan.
The limited warranty period for replacement parts, and for Fans repaired or replaced under this limited
warranty, shall continue for the remainder of the original warranty period.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any
product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty
does not cover (a) normal maintenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty
installation or installation contrary to recommended installation instructions.
The duration of an implied warranty is limited to the one-year period as specified for the express
warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above
limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL
BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE
SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state
to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number
stated below, (b) give the model number and part identification and (c) describe the nature of any
defect in the product or part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - FLUORESCENT FAN / LIGHT

Page 1MODEL 744FLNT WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit only in t

Seite 2 - INSTALLATION

Page 2MODEL 744FLNT Two of the most common ways to connect ductwork to the unit.ROOF CAP **4-IN. ROUNDELBOW **4-IN. ROUNDDUCT **WALLCAP **Installer:

Seite 3 - MODEL 744FLNT

Page 3MODEL 744FLNT HORIZONTAL POWER CABLE CONNECTIONVERTICAL POWER CABLE CONNECTIONWIRING PLATEWHITETOWHITEBLUE (FAN)TOBLACKTOP / BACKOF HOUSING3-W

Seite 4 - SERVICE PARTS

Page 4MODEL 744FLNT SERVICE PARTS KEY NO. PART NO. DESCRIPTION 1 97014185 Damper / Duct Connector 2 97016382 Housing Assembly 3 98003036

Seite 5 - FLUORESCENTE EMPOTRADO

Page 5MODEL 744FLNT ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS SIGUIENTES PRECAUCI

Seite 6 - INSTALACIÓN

Page 6MODEL 744FLNT Dos de las maneras más comunes de conectar conductos a la unidad.TAPA DE TECHO **CONDUCTO REDONDO DE 4 pulg. **CODO REDONDO DE 4

Seite 7

Page 7MODEL 744FLNT CONEXIÓN DEL CABLE ELÉCTRICO HORIZONTALCONEXIÓN DEL CABLE ELÉCTRICO VERTICALPLACA DE CABLEADOBLANCO CON BLANCOAZUL (VENTILADOR)

Seite 8 - PIEZAS DE REPUESTO

Page 8MODEL 744FLNT PIEZAS DE REPUESTOCLAVE PIEZA Nº. DESCRIPCIÓN Nº. 1 97014185 Conector del regulador de tiro/conducto 2 97016382 Conjun

Kommentare zu diesen Handbüchern

Keine Kommentare